------------------ Need Any Help Call Amarbir @ 09815000133 For Discussions

----------------- " Data Recovery eXpert ,Engineer , Designer And Repairmen "

----------------- " Cash On Delivery " COD " Facility Is Not Available Sorry "

Catalog
(empty)
 
I Will Pay By
Select :
Survey
Kindly Rate Website Access Speed ?
!!! New Products !!!
!!! Deal Of The Day !!!
(Excellent Deal)
!!! Deal Of The Week !!!
!!! Deal of The Month !!!
!!! CEO Amarbir's Pick !!!






Search
Printer friendly version Printer friendly version

Metravi - Digital Multimeter [ Metrasafe-15 ]

Rate it
Rs :4,400/-
In Stock : yes
Shipping Weight For Freight Calculation: 0.74 kg
Qty:  

 

Overload protection up to 1200V DC / AC RMS in the AC/DC Voltage range.Overload protection up to 20A DC/AC RMS by fast blow fuse in the AC/DC Current range. Overload protection up to 600V DC / AC RMS in the capacitance, Frequency, Temperature, Resistance, Continuity and Diode Test Range. (1000V DC/AC RMS protection in Metrasafe 16 only). The instrument has overload protection up to 20A DC/AC RMS in the Voltage Range and 1000V DC/AC RMS in the Current Range. Surge Protection of 8 kV peak IEC 61010 'O' Ring Seal body. The instrument has IP-67 Protection making the body water proof even if dipped in 1m. deep water for 30 mins. Double molded injection body with rubber lining to provide insulation against electrical shocks and anti-slip grip. Confirms to EN61010-1, CAT IV 600V, CAT III 1000V. Two Years' Warranty against any manufacturing defects. 

 

General Specifications :

Insulation : Class2, Double insulation.
Overvoltage category : CAT IV 600V, CAT III 1000V
Maximun Voltage between any terminal & earth ground : 1000V DC/AC RMS
Surge Protection : 8kV peak IEC 61010
Display : 4000 counts Backlit LCD display, 21mm high
Polarity : Automatic, (-) negative polarity indication.
Over-range : "OL" mark indication.
Low battery indication : A Battery symbol is displayed when the battery voltage drops below the operating level.
Measurement rate : 2 times per second nominal.
Auto power off : Meter automatically shuts down after approx. 30 minutes of inactivity.
Operating environment : -10oC to 50oC (14oF to 122oF) @ < 70% R.H.
Storage temperature : -30oC to 60oC (-4oF to 140oF) @ < 80% R.H.
Relative humidity : 90% (0oC to 30oC); 75%(30oC to 40oC); 45%(40oC to 50oC);
Operating : 3000m
Storage : 10,000m
Waterproof : IP67
Pollution degree : 2
Safety : The instrument complies with EN61010-2-32
Power : One 9V battery , NEDA 1604, IEC 6F22.
Dimensions : 182 (H) x 82 (W) x55 (D) mm
Data Hold : To freeze the displayed data
Max/Min : Records max/min data
 

Technical Specifications :

Accuracy is given at 18oC to 28oC (65oF to 83oF), less than 70 % RH
 
DC Voltage (Auto Ranging)

Range Resolution Accuracy
400.0mV 0.1mV
4.00V 1mV
40.00V 10mV ± 0.5% of rdg ± 2 digits
400.0V 100mV
1000V 1V ± 0.8% of rdg ± 2 digits

Input Impedance :  7.8MΩ.
Maximum Input :  1200V DC or 1200V AC rms.
 
AC Voltage (Auto-ranging) (T-RMS for Metrasafe 16 only)

Range Resolution Accuracy
400.0mV 0.1mV
4.000V 1mV
40.00V 10mV ± 0.8%of rdg ± 3 digits
400.0V 100mV
1000V 1V ± 1.2%of rdg + 5 digits

Input Impedance :  7.8MΩ.
Frequency Range :  50 Hz to 60 Hz
Maximum Input : 1200V DC or 1200V AC rms.

 
DC Current (Auto-ranging)

Range Resolution Accuracy
400.0uA 0.1uA
4000uA 1uA
40.00mA 10uA ± 2.5% of rdg + 3 digits
400.0mA 100uA
20A 10mA ± 1.2% of rdg + 3 digits

Overload Protection : 0.5A / 1000V and 20A /500V Fuse.
Maximum Input :  400uA DC on uA range 400mA DC on mA range 20A DC on 20A range.

 

AC Current (Auto-ranging) (T-RMS for Metrasafe 16 only)

Range Resolution Accuracy
400.0uA 0.1uA
4000uA 1uA
40.00mA 10uA ± 1.5% of rdg + 5 digits
400.0mA 100uA
20A 10mA ± 3.0% of rdg + 5 digits

Overload Protection : 0.5A / 1000V and 20A / 500V Fuse
AC Response : 50 Hz to 400 Hz
Maximum Input : 400uA AC rms on uA 400mA AC rms on mA 20A AC rms on20A range.
 

Resistance [Ω] (Auto-ranging)

Range Resolution Accuracy
400.0Ω 0.1Ω ± 0.8% of rdg + 5 digits
4.000kΩ
40.00kΩ 10Ω ± 0.8% of rdg + 2 digits
400.0MΩ 100Ω
4.000MΩ 1kΩ
40.00kΩ 10kΩ ± 2.5% of rdg +8digits

Input Protection :  600V DC or 600V AC rms

                              1000V DC or AC RMS in Metrasafe 16 only.
 
Capacitance (Auto Ranging)

Range Resolution Accuracy
4.000nF 1pF ± 10% of rdg + 10 dgts
40.00nF 10pF ± 3.0% of rdg + 5 dgts
400.0nF 0.1nF
4.000uF 1nF ± 5.0% of rdg+20 dgts
40.00uF 10nF
400.0uF 0.1uF
4.000mF 0.001mF ± 5.0% of rdg + 7 dgts
40.00mF 0.01mF

Input Protection : 600V DC or 600V AC rms
                              1000V DC or AC RMS in Metrasafe 16 only.
 

Frequency (Auto Ranging )

Range Resolution Accuracy
40.00kHz 1Hz
400.0kHz 10Hz ± 1.2% of rdg + 3 dgts
40.00MHz 100Hz
4.000kHz 1kHz ± 1.5% of rdg + 4 dgts

Sensitiviy : >0.5V RMS while £ 1MHz ;
Sensitivity : >3V RMS while >1MHz ;
Overload protection : 600V DC or AC rms
                                     1000V DC or AC RMS in Metrasafe 16 only.
 

Temperature

Range Resolution Accuracy
-20oC~+760oC 1oC ±3% of rdg ±5dgts
-4oF~+1400oF 1oF ±3% of rdg ±9dgts

Sensor : Type K Thermocouple
Overload protection : 600V DC or AC rms
                                     1000V DC or AC RMS in Metrasafe 16 only.
 

Diode Test

Test Current
Resolution Accuracy
1mA typical/Open MAX.3V 1mV ±10% of rdg + 5 digits

Open circuit voltage :  MAX. 3V DC
Overload protection : 600V DC or AC rms
                                     1000V DC or AC RMS in Metrasafe 16 Only
 

Audible continuity

Audible threshold : 35W Test current MAX. 1.5mA
Overload protection : 600V DC or AC rms.
                                     1000V DC or AC RMS in Metrasafe 16 only.
 

Warranty :  As Per Manufacturer [ Metravi's Policy FOB  India ]

 

Note :

         We Get These Products On Case To Case Basis [ Backorder]

         If You Like To Buy This Please Call Amarbir @ 09815000133

         If The Deal Matures Between You/Us [ Kindly Pay And We Will Arrange ]

         Taxes Like VAT , Shipping Charges Are Extra Above This Base Pricing

         Like To Know About The Product -> Go To Metravi's Website

         Have Something To Discuss Visit -> Kindly Post In The Lynx Forum

 

Any questions?

Please use the following form to request information.

Your name:

Email

Please specify your question about Metravi - Digital Multimeter [ Metrasafe-15 ]:


Type the numbers you see in the picture below
code

Local Time @ India






Follow lynxgroup on Twitter






Language
Blog / News
18.09.2014 12:20:42
15.09.2014 01:36:48
14.09.2014 09:41:21
09.09.2014 03:07:55
14.08.2014 23:54:17
13.08.2014 00:14:52
30.07.2014 02:51:41
20.07.2014 10:19:13
20.07.2014 04:00:21
05.07.2014 12:14:50
05.07.2014 04:31:51
05.07.2014 00:48:58
04.07.2014 09:13:40
01.07.2014 10:58:16
25.06.2014 13:51:01
25.06.2014 13:40:44
21.06.2014 14:03:01
12.06.2014 09:10:59
04.06.2014 11:14:51
04.06.2014 01:05:05
21.05.2014 00:20:31
21.05.2014 00:18:59
14.05.2014 01:33:11
10.05.2014 09:29:01
07.05.2014 07:47:10
07.05.2014 01:47:06
06.05.2014 05:31:59
06.05.2014 03:03:59
05.05.2014 10:08:17
03.05.2014 00:43:42
22.04.2014 22:29:41
02.04.2014 02:40:50
23.03.2014 11:25:52
17.03.2014 01:56:04
15.03.2014 00:30:21
Subscribe for email newsletter (blog):